The Inverter RS Smart Solar is a combination of a powerful 48VDC, 6kVA 230VAC inverter, and a high voltage, 80-450VDC, 4kW MPPT solar charger. Thanks to its modern design and high-frequency technology the inverter only weighs 11kg and has excellent efficiency, low standby power, and very quiet operation.
The inverter is equipped with a display to read out the battery, inverter, and solar charger details. These parameters can also be read out via Bluetooth by the VictronConnect App. In addition to this, the inverter has a VE. Direct and a VE. Can Port, for connection to a GX device for system monitoring.
Off-Grid solar inverter The Inverter RS Smart Solar 48/6000 is a 48V 6kVA Inverter with 450VDC 4kWp PV input. It is used in
off-grid solar applications where AC power is required.
Combination of an inverter, bi-directional DC-DC converter, and MPPT The inverter produces a perfect sine wave, able to supply high-powered appliances. It is supplied by
a bi-directional DC-DC converter, that can either charge the battery when excess solar power is
available or convert from the battery when it is needed.
Wide MPPT voltage range 80 – 450VDC, with a 120VDC PV startup voltage.
Lightweight, efficient and quiet Thanks to high-frequency technology and a new design this powerful inverter weighs only 11kg. In
addition to this, it has excellent efficiency, low standby power, and a very quiet operation.
Display and Bluetooth The display reads battery, inverter, and solar charge controller parameters.
The same parameters can be accessed with a smartphone or other
Bluetooth enabled device. In addition, Bluetooth can be used to
set up the system and to change settings with VictronConnect.
VE. Can and VE. Direct port For connection to a GX device for system monitoring, data logging, and remote firmware updates.
Built-in PV isolator Both parallel PV strings connected to the MC4 plugs can be safely isolated with the large built-in
switch on the bottom of the unit.
I/O Connections Programmable Relay, temperature sensor, and voltage sensor connections. The remote input can
also, be configured to accept the Victron small BMS.
- Can be adjusted to 60 Hz
- Protection key:
- output short circuit
- overload
- battery voltage too high
- battery voltage too low
- temperature too high
- 230 VAC on inverter output
- A programmable relay can be set for general alarm, DC under voltage, or Genset start/stop
function. DC rating: 4A up to 35VDC and 1A up to 70VDC
- Normal operation is regulated to 18A, with maximum reverse polarity protection 20A.
- MPPT operating range is also constrained by battery voltage - PV VOC should not exceed 8x
battery float voltage, e.g. a 50V battery voltage maximum should have a 400V maximum PV array.
– see the product manual for further information.
- The minimum start-up voltage is 41V. Inverter shutdown can be set as low as 32V DC but may shut
down on low AC output voltage (due to load). The over-voltage disconnect is 65.5V. Charger setpoint can be set to max 62V. The charge current derates above 57V.