There are 4 options for this Remote Panel
-
Manual Control
When the load output is set on Manual Control (default setting), the output can be switched ON or OFF with the orange switch button on the Charge Controller. The low voltage cut-off is also operational.
-
Light On/Off
This is a simple load output On/Off option, based on the solar input voltage of the Controller (= output voltage of the solar panel).
• When, at dusk, the input voltage of the Controller becomes lower than the light On voltage (default 0.50V), the load output is switched on.
• When, at dawn, the input voltage of the Controller becomes higher than the light Off voltage (default 0.40V), the load output is switched off.
• In order to prevent unwanted switching a confirmation time (DeT) can be set: default 10 minutes, range 0 – 99 minutes.
-
Light On+Timer
This option allows for a pre-set On-time after dusk and a pre-set Off-time before dawn. The dusk and dawn switching moments and confirmation time are set as under option 2.
The remaining parameters are set as follows:
• NightTime: the initial setting of the night duration, the controller will subsequently adjust NightTime to the actual duration of the night.
• On-Time 1: On period after dusk.
• On-Time 2: On period before dawn.
-
Time control
This option uses the internal clock (see section 5.6in manual) to set one (Time1 only) or two on-time periods.